Q3.Troubleshooting process for firmware upgrade failure - Encoder Series - kiloview

Q3.Troubleshooting process for firmware upgrade failure

12/29/2025 / 1623

1. Check the firmware file format and naming

Is there a prompt saying 'non bin file uploaded' during upgrade?

Please upgrade using Google Chrome on a Windows computer to avoid browser compatibility issues.

→ Ensure that the firmware file name has not been modified (such as no spaces, special characters, or suffixes (1), etc.).

If using an Apple computer, it is recommended to upgrade to a Windows system.

2 . Verify that the firmware version matches the device model

Prompt 'firmware version model error'?

It may be caused by a mismatch between the firmware version and the device model.

Firstly, confirm the purchased product model and find the corresponding firmware to download and upgrade.

For example, E1 and E1-NDI (supporting NDI protocol) products require downloading the corresponding firmware that supports NDI.

For example, products with NDI markings in the following image are considered to support NDI.
image.png

  • Login to the official website to confirm the device model (if E1/NDI version requires downloading the corresponding firmware with NDI identification).
  • Download Path: KiloView Official Website - Data Download

3. Clear browser cache and force refresh

Prompt 'network error' or unresponsive upgrade?

This situation is mainly caused by browser caching, which aims to speed up webpage loading by storing previously accessed resources and reducing requests to the server.

However, if the data in the cache is outdated, damaged, or does not match the current webpage, it may cause display issues.

As a result, the device cannot be upgraded normally.

The following methods can be used to repair it

Press Ctrl+F5 (Windows) or CMD+Shift+R (Mac) to force the page to refresh.

→ Clear browser cache (Settings → Privacy → Clear cached data).

4 . Check if the upgrade path requires an intermediate version

Display 'Upgrade successful' but version number not updated?

This situation mostly occurs when the changes in the old and new versions are significant and cannot be directly upgraded. It is necessary to first upgrade to the intermediate intermediate version before upgrading to the latest version.

Partial cross version upgrades (such as D350 from 1.00.0002 to 1.01.0027) require upgrading to an intermediate version (such as 1.01.0018) first.