Q7.Failure to decode SRT, RTMP streams after upgrade - Decoder Series - kiloview

Q7.Failure to decode SRT, RTMP streams after upgrade

12/30/2025 / 717

Problem Background

After upgrading RD350, RD260, D350, D260 decoders to version 2.02, SRT and RTMP streams that can be decoded normally cannot be decoded normally, and the word “NO Video” is displayed.
image.png

Common Troubleshooting Approaches

  1. Due to the new “Response Speed” in firmware version 2.02, the default reconnect time is 5 seconds, which causes SRT and RTMP protocols to pull streams again when they have not been successfully pulled, resulting in decoding failure
  2. Login to the backend of the device webpage and select the gear icon at the top right of the source.
    image.png
  3. Click “Response Speed”, it is recommended to set more than 15 seconds in SRT, RTMP decoding, and then adjust according to the actual network conditions.
    image.png