Problem Background

Maintenance IP is the network address of the device's network port for management and maintenance, through which users can log in the device's Web management page for parameter configuration, status monitoring and other operations. The default maintenance IP of the device is a fixed address preset by the factory, which will be automatically restored to the default value after restoring the factory settings, and users can also customize and modify it according to their needs in the Web management interface.

Default Maintenance IP Address

network port Default Maintenance IP subnet mask
network port 1 192.168.1.168 255.255.255.0
network port 2 192.168.2.168 255.255.255.0

Notes on using the default maintenance IP to log in to the Web management page

  1. Network segment matching: When logging in with the default maintenance IP (e.g. 192.168.1.168 or 192.168.2.168), you need to make sure that your computer's network configuration is in the same network segment as that IP.

    • If connecting to port 1, the computer's IP should be set to 192.168.1.* (* is a number between 1-255 except 168);
    • If connecting to port 2, the computer's IP should be set to 192.168.2.* (* is a number between 1-255 except 168).
  2. You need to synchronize the computer network after IP modification: After modifying the IP of the device in the Web management page, you need to restore the network configuration of the computer to the IP of the actual working network to avoid affecting the normal use.

  3. Commonality of default address: Even if you have not viewed the current network port through the touch screen, you can directly try to access it using the default IP (192.168.1.168) of network port 1, or if you are connected to network port 2, you can try to access it using the default IP (192.168.2.168) of network port 2.

Restoring Factory Settings to Default Maintenance Impact
When the device performs the “Restore Factory Settings” operation via physical buttons (RESET button) or the Web management page, the maintenance IPs of NIC 1 and NIC 2 will be automatically restored to the default values (i.e., 192.168.1.168 for NIC 1 and 192.168.2.168 for NIC 2).

Access to the Web

  1. Open your computer's browser and enter the corresponding maintenance IP of the device in the address bar (e.g. 192.168.1.168 for network port 1, 192.168.2.168 for network port 2, or a customized maintenance IP);
  2. After enter, if the login interface appears, enter the default or modified user name and password of the device (the default is often admin/admin), you can enter the Web management terminal to operate the device.