Q2.Devices (e.g., P-series encoders) cannot bind to KiloLink Server Pro, prompting "Connection Failed"? 12/26/2025 / 814 A1. Confirm the server IP, port, and authorization code are correct. Check the authorization code on the server's "Device Management -> Add Device" page. Confirm the "Server IP" filled in on the device is the server's public/private IP, and the "Service Port" matches the "Link port" from the server deployment (default 50000, must be an even number). A2. Check if the device and server versions are compatible. The firmware version of P-series devices is incompatible with KiloLink Server Pro (e.g., older device firmware does not support the new server's aggregation protocol). It is recommended to upgrade both P-series devices and KiloLink Server Pro to the latest versions available on the official website. A3. Confirm port forwarding is configured correctly (device in external network scenario). If the device and server are not on the same LAN, lack of port forwarding on the server will prevent the device from connecting. Solution: Log in to the router of the server's network, go to "Port Forwarding" settings, and add a rule: - External Port / Internal Port both fill in the server's Link port (e.g., 50000). - Internal IP fill in the server's local private IP (check using the ip addr command). - Protocol select "UDP". Save and restart the router for testing. Previous:Q1.Cannot access the KiloLink Server Pro via browser, showing "Connection Failed" or "Page Not Found"? Next:Q3.Prompt "Port is occupied" during KiloLink Server Pro deployment, or the port is unavailable after service starts?