Q3.Prompt "Port is occupied" during KiloLink Server Pro deployment, or the port is unavailable after service starts? - P-Series & Kilolink Server Pro - kiloview

Q3.Prompt "Port is occupied" during KiloLink Server Pro deployment, or the port is unavailable after service starts?

12/26/2025 / 709

A1. Check if the port is occupied by another program.

Default ports like 80 (Web) and 50000 (device link) might be occupied by programs like Apache, Nginx.Solution: Log in to the server terminal, execute netstat -tuln | grep port_number (e.g., grep 80), check if a process is occupying the port. If yes, note the Process ID and execute kill -9 Process_ID to stop the occupying program.

A2. Reconfigure to use an unoccupied port.

If the program occupying the port cannot be stopped (e.g., essential system service), the server port needs to be changed.Solution: Re-run the deployment script. During the "Web port" or "Link port" configuration steps, enter an unoccupied port (Link port must be even). After deployment, ensure the firewall also opens the new port. The device end must also be filled with the new Link port.