Q18.The device does not power on after connecting to the power source. The power light is off and there is no response. - P-Series & Kilolink Server Pro - kiloview

Q18.The device does not power on after connecting to the power source. The power light is off and there is no response.

12/26/2025 / 616

A1. Check if the power adapter connection is secure.

  • Troubleshooting Reason:The power adapter is not plugged in firmly (loose on the device end or the socket end), causing the device to not receive power.
  • Solution:1. Confirm the DC plug of the power adapter is fully inserted into the device's "Power Interface" and screwed tight (if it has a locking screw). 2. Check if the other end of the adapter is plugged firmly into the power socket; try a different socket (e.g., switch from a power strip to a wall outlet).

A2. Confirm that the original power adapter is being used.

  • Troubleshooting Reason:Using a non-original adapter (e.g., incorrect voltage/amperage, such as using a 12V/2A adapter to replace the original 12V/3A) provides insufficient power, preventing the device from starting.
  • Solution:1. Check the label on the bottom of the device to confirm the original adapter specifications (P3/P3-mini original adapter is typically 12V/3A). 2. Replace it with the original adapter. If the adapter is lost, contact the dealer or visit the Kiloview official website to purchase an original accessory.

A3. Check if the power adapter is damaged.

  • Troubleshooting Reason:A broken adapter cable, damaged interface, or internal fault prevents it from supplying power.
  • Solution:1. Inspect the adapter cable for obvious damage, breaks, or bending, and check the interfaces for rust or deformation. 2. Use a multimeter to measure the adapter's output voltage (requires operation by a professional), or test with another original adapter with the same specifications. If the device powers on after replacement, it indicates the original adapter is damaged.