Q7.P3Mini reports error 'Invalid node type' when upgrading from the server - P-Series & Kilolink Server Pro - kiloview

Q7.P3Mini reports error 'Invalid node type' when upgrading from the server

12/30/2025 / 628

Problem Background

After connecting P3 Mini to Kilolink Server Pro, the user wants to directly upgrade the firmware of P3 Mini from the server.

After uploading the firmware to the server, if the user checks the corresponding firmware, the upgrade fails with the error "Invalid node type"
image.png

Reason for the problem

The root cause of this issue is the compatibility problem between the firmware version of the P3 Mini device and the Kilolink Server Pro.

1. Incompatible firmware version: When the firmware version of the P3 Mini device is lower than 1.01.0041, the device type is identified as P3mini, but starting from version 1.01.0041, the device type is changed to P3 mini.

Due to differences in device type recognition by Kilolink Server Pro, an 'Invalid node type' error occurred during the upgrade process.

2. Device type change: The change in device type means that P3 Mini devices below version 1.01.0041 cannot be upgraded to version 1.02.0006 or higher through Kilolink Server Pro.

This type of device can only be firmware upgraded through the Web UI (web interface).
image.png

image.png

Solution

**Option 1: ** Upgrade device firmware through Web UI

For P3 Mini devices below version 1.01.0041, users need to use Web UI for firmware upgrade.

Please follow the steps below:

  1. Open the browser and access the web UI address of P3 Mini.
  2. Log in to the web UI.
  3. Enter the firmware upgrade page, select and upload the target firmware version (such as 1.02.0006).
  4. Complete the firmware upgrade according to the prompts on the web UI.

**Option 2: ** Upgrade to version 1.01.0041 or higher before using Kilolin Server Pro for upgrade

If users wish to continue using Kilolink Server Pro for subsequent firmware upgrades, they need to manually upgrade the device's firmware to version 1.01.0041 or higher first.

The specific steps are as follows:

  1. Use web UI or other methods to upgrade the device to version 1.01.0041 or higher.

After the upgrade is completed, the device type will automatically change to P3 mini, and subsequent firmware upgrades can be performed through Kilolink Server Pro.

preventive measure

Before upgrading the firmware using Kilolink Server Pro, please ensure that the firmware version of the P3 Mini device is 1.01.0041 or higher.

If the device version is lower than this version, please first upgrade to this version through the web UI.

Regularly check the firmware version of the device to avoid upgrade failures caused by version differences.

Other precautions

Please ensure that the firmware file is correct and error free to avoid upgrade failures caused by file corruption.

During the upgrade process, please ensure a stable network connection between the device and the server to prevent firmware upgrade failures caused by network interruptions.