【Frame Synchronization Support Across Station's SDI, HDMI, and Network Streaming Interfaces】

Document Purpose

This document aims to help you quickly verify whether Station's SDI, HDMI, and network streaming all support frame synchronization.

Applicable Products/Versions:【P3/P3mini,version 1.23 and above 】

【Station,version 1.00 and above 】

Issue Description and Applicable Scenarios

You can refer to this document when encountering the following situations:

This document aims to help you quickly understand whether Station's SDI, HDMI, and network streaming all support frame synchronization.

**Summary:**​Based on Station version 1.0, only the 4 SDI interfaces support frame synchronization. HDMI and network streaming currently do not support frame synchronization.

Solution

The steps to enable frame synchronization are as follows:

3.1 Binding P-Series Products to Station Configuration

Step 1: Log in to the web backend of the P3 mini or other P-series devices, select Home ​-> Aggregated Streaming -> Kilolink gear icon .

**Step 2:**​ Enable the Kilolink Server service, then enter Station's IP address, service port 50000, and the authorization code.

##

**Step 3:**​Log in to the Station web backend, add P3 or P-series devices, click Management ​-> Devices ​-> Add Device .

**Step 4:**​Fill in the name and the P-series product serial number. Generate an authorization code. This authorization code must be entered into the P3mini's aggregation configuration. Ensure they match.

######

3.2 Aggregated Streaming from P-Series to Station

Step 5:​ When the page shows "Kilolink Connected," go to the P-series device's web backend to verify the Kilolink connection is normal. Click Aggregated Streaming to enable it. If the aggregated status shows a time counter ticking, it proves the streaming is successful. Please note: if the aggregated status shows no time counter ticking, you need to click the aggregated streaming switch again to restart the aggregated streaming. The aggregated stream source from the P-series will then be added to Station's output page.

**Step 6:**​In the Station web backend, click Management ​-> Output ​-> Sources ​ to check that the source from the P-series product has been successfully added.

3.3 Station Frame Synchronization Decoding Output Configuration

**Step 7:**​In the P-series web backend, under Video Encoding , change the SEI timecode to System Time , display the frame synchronization option, and select Default .